18079123789
18600469666
18079123789
logo
A solution provider focusing on infant oxygen inhalation and breathing equipment
contact us
One-touch dial
One-click navigation
Wechat
Rirui Medical
logo
A solution provider focusing on infant oxygen inhalation and breathing equipment

Home > Technical

Introduction to the function of the pass-through temperature measuring door

release time: 2022-08-06 09:45:36

Views: 278

Pass-through temperature measuring door (RGY-8000A)


 


Features:


 


Temperature sensor probe: thermal infrared imaging probe, which has the advantages of high sensitivity, high pixel, high resolution area array imaging, etc.;


High pass rate: normal and slow walk through, face side view indicator light, pass rate ≈ 40-60 people/min;


Prevent missed inspection: The product design is ergonomic, which ensures that the inspected person cannot avoid the probe;


Detection accuracy: The detection result can be accurate to two decimal places, under normal room temperature, the temperature error is ±0.5℃.


Irradiation angle: large-area conical sector.


System function: when passing people, green light prompts; when high temperature alarms, red light prompts; number of people recording;


Sound and light alarm: When the subject passes through the temperature measurement door, when the body temperature is abnormal, the red signal light flashes, and a sound prompt is issued to the detection personnel, and the number of alarms can be stored.


Intelligent statistics: intelligent passenger flow and alarm counting functions, which can automatically count the number of people passing by and the number of alarms;


Very low power consumption: less than 13W under normal working power;


Detection height: The probe can move up and down to adapt to people of different heights and ages;


Simple to use: portable installation, ready to use;


Scope of application: Widely used in railway stations, bus stations, hospitals, schools, office buildings and other public places.


 


technical parameter:


 


Working mode: 01 normal passing mode; 02 jogging side mode; 03 stop mode;


Detection distance: <50CM


Temperature measurement range: 25℃~48℃;


Temperature measurement error: ±0.5°C (at room temperature), ±0.3°C in a specific mode (at constant room temperature)


Resolution: 0.02℃


Working temperature: -25℃~55℃;


Working humidity: 95%, no condensation;


Working voltage: wide voltage AC180-250V, 50-60HZ;


Power: <20W;


Net weight: 50KG;


Channel size: 1950mm (height) × 620mm (width) × 500mm (depth);


Dimensions: 2150mm (height) × 700mm (width) × 500mm (depth).